ASE-7816 Biosensors, 5 cr

Lisätiedot

Suitable for postgraduate studies.

Vastuuhenkilö

Jukka Lekkala

Opetus

Toteutuskerta Periodi Vastuuhenkilö Suoritusvaatimukset
ASE-7816 2016-01 3 - 4 Dhanesh Kattipparambil Rajan
Jukka Lekkala
Ville Rantanen
Passed exercises, laboratory work and examination.

Osaamistavoitteet

After having passed the study module the student will understand the physical operating principles of biosensors. He/she knows the basic terms and definitions. He/she understand the biology of the sensing elements and specific molecular recognition principles. The student is able to give examples of different biosensor structures and is able to understand and analyse measurement connections and amplifiers that have been used with them. The student can model and simulate the function of simple biosensors. He/she understands the limitations of the sensors. The student can list different biosensors and of their application areas.

Sisältö

Sisältö Ydinsisältö Täydentävä tietämys Erityistietämys
1. History of biosensor development, applications and requirements of biosensors.   Definition of concentrations, sampling principles    
2. Principles of molecular recognition, structure of enzyme and antibody, immunosensors, modeling of reactions, immobilization techniques.   Immune response, bacteria and viruses, self-assembled membranes   Molecular modeling, Langmuir-Blodgett -thin film technology  
3. Detection methods, electrodes, ISFET, optical sensors, Surface Plasmon Resonance (SPR) sensor, piezoelectric resonators and thermal sensors.   Principles of electrochemistry, operation principles of optical fibre sensors, modeling of SPR sensor.    
4. Miniaturization, biocompatibility, microanalyzers and BioMEMS structures.   Biomaterials, Micro ElectroMechanical systems (MEMS)   
5. Examples of commercial biosensors.      

Ohjeita opiskelijalle osaamisen tasojen saavuttamiseksi

The grade of the course is determined by examination. If the student knows the core material well, there is a possibility to pass the course with grade 3. The supplementing knowledge must be also known in order to reach a grade of 4 or 5. If in the core material there are minor shortcomings, the student will have an opportunity for the grade 1 or 2 depending on the amount of the shortcomings. Activity in exercises gives the opportunity for the additional points in the examination. If there are considerable shortcomings in the knowledge of the core material, the student will not pass the course.

Arvosteluasteikko:

Numerical evaluation scale (0-5)

Osasuoritukset:

Completion parts must belong to the same implementation

Oppimateriaali

Tyyppi Nimi Tekijä ISBN URL Lisätiedot Tenttimateriaali
Book   Biomolecular sensors   Gizeli and Lowe   0-7484-0791-X       Yes   
Book   Engineering Biosensors - Kinetics and Design Applications   Ajit Sadana   0-12-613763-3     Chapters 2 & 3   Yes   
Lecture slides   Biosensors   Jukka Lekkala         Yes   

Esitietovaatimukset

Opintojakso P/S Selite
ASE-3036 Microsensors Advisable    

Tietoa esitietovaatimuksista
Chemistry and biochemistry studies help understanding the biological part of biosensors. The english courses are for international students.



Vastaavuudet

Opintojakso Vastaa opintojaksoa  Selite 
ASE-7816 Biosensors, 5 cr BMT-7816 Biosensors, 5 cr  
ASE-7816 Biosensors, 5 cr MIT-4070 Biosensors, 5 cr  
ASE-7816 Biosensors, 5 cr ASE-7816 Biosensors, 5 cr  
ASE-7816 Biosensors, 5 cr MIT-4076 Biosensors, 5 cr  

Päivittäjä: Jokinen Heikki, 11.04.2016